1kW Fuel Cell T-Series
• 1kW Backup Energy Output – Perfect for off-grid telecom towers, defense systems, and remote infrastructure backup
• Highly Integrated System – Includes fuel cell stack, DC/DC converter, hydrogen sensor, pressure regulator, cables, and connectors for independent operation
• Modular Solution – Connects with other T-Series stacks, scale your system as energy demands grow
• Advanced System Monitoring – Built-in RS232 connectivity and software allow real-time tracking and voltage range adjustment
• Continuous Operation Capability – Simple integration of a 48V battery enables fully autonomous energy delivery without manual oversight
• Global Delivery & Support – Backed by Horizon’s technical expertise and international logistics network
1000W Fuel Cell Stack T Series
Additional Information
T Series fuel cell systems typically come with a controller, FC connector, RS232 cable, FC +/- cables, output +/- cables, pressure regulator, 6mm PTFE tube, Ferrule Connectors, and a hydrogen sensor.
Customers are required to fill out quote request forms for this fuel cell stack, since Horizon carries a limited number of these at any given time. By submitting the form, we will be able to set proper delivery expectations as well as work with you to create a package to ensure you have all of the fuel cell stack accessories in order to facilitate project development.
List of T-1000 components:
1 x 1000W fuel cell stack
1 x 1000W controller
1 x fuel cell connector
1 x RS232 cable
1 x FC +/- cables
1 x pressure regulator
2 x 6mm PTFE tube (1m)
20 x ferrule connectors
1 x hydrogen sensor
1000W Fuel Cell Stack T Series Quick Product Facts
Hydrogen Pressure
Hydrogen must be fed into the fuel cell stack at a pressure of 0.55 to 0.75bar.
Ambient Temperature
The fuel cell stack operates best in a temperature ranging from 0 to 40° C.
FC Stack Weight
The stack (including fan and casing) weighs 40lbs / 18kg.
System Efficiency
At peak power the efficiency of the system is 42%.
Hydrogen Purity
A fuel of gaseous hydrogen at a minimum purity level of 99.995% is required.
Voltage Output
The voltage can be adjusted to between 43.2 and 57.6 volts direct current.
Packing Information
| T-1000 | T-2500 | T-3000 | T-5000 | T-10000 | |
|---|---|---|---|---|---|
| Power rating | 0 to 1000 W @ 20°C and 101.3 kPa | 0 to 2500 W @ 20°C and 101.3 kPa | 0 to 3000 W @ 20°C and 101.3 kPa | 0 to 5000 W @ 20°C and 101.3 kPa | 0 to 5000 W @ 20°C and 101.3 kPa |
| Current Rating | 0 to 19A @54V | 0 to 47A @54V | 0 to 56A @54V | 0 to 47A x 2 @54V | 0 to 47A x 4 @54V |
| Voltage Adjustable | 43.2 to 57.6 VDC | 43.2 to 57.6 VDC | 43.2 to 57.6 VDC | 43.2 to 57.6 VDC | 43.2 to 57.6 VDC |
| Voltage Ripple | ±1V | ±1V | ±1V | ±1V | ±1V |
| Controller Dimension (WxDxH) | 430mm x 550mm x 88mm | 430mm x 550mm x 88mm | 430mm x 550mm x 150mm | (430mm x 550mm x 88mm) x 2 | (430mm x 550mm x 88mm) x 4 |
| Stack Dimension (WxDxH) | 430mm x 550mm x 88mm | 430mm x 550mm x 356mm | 430mm x 550mm x 356mm | (430mm x 550mm x 356mm) x 2 | (430mm x 550mm x 356mm) x 4 |
| Controller Weight | 10 kg | 13.5 kg | 15 kg | 13.5 x 2 kg | 13.5 x 4 kg |
| Stack Weight | 18 kg | 40.3 kg | 40.3 kg | 40.3 x 2 kg | 40.3 x 4 kg |
| Ambient temeprature * | -10⁰C to +45⁰C standard | -10⁰C to +45⁰C standard | -10⁰C to +45⁰C standard | -10⁰C to +45⁰C standard | -10⁰C to +45⁰C standard |
| Recommended cold start temp | More than 5⁰C | More than 5⁰C | More than 5⁰C | More than 5⁰C | More than 5⁰C |
| Relative Humidity | 0‐95% Non‐Condensing | 0‐95% Non‐Condensing | 0‐95% Non‐Condensing | 0‐95% Non‐Condensing | 0‐95% Non‐Condensing |
| Communications | RS232 | RS232 | RS232 | RS232 | RS232 |
| Standby Power Consumption | Approximately<3% at peak power (DC) | Approximately<3% at peak power (DC) | Approximately<3% at peak power (DC) | Approximately<3% at peak power (DC) | Approximately<3% at peak power (DC) |
| Reactants | Hydrogen and Air | Hydrogen and Air | Hydrogen and Air | Hydrogen and Air | Hydrogen and Air |
| Cooling | Air (integrated cooling fan) | Air (integrated cooling fan) | Air (integrated cooling fan) | Air (integrated cooling fan) | Air (integrated cooling fan) |
| H2 inlet pressure | 0.55-0.75bar | 0.55-0.75bar | 0.55-0.75bar | 0.55-0.75bar | 0.55-0.75bar |
| Hydrogen purity | ≧99.95% dry H2 | ≧99.95% dry H2 | ≧99.95% dry H2 | ≧99.95% dry H2 | ≧99.95% dry H2 |
| Consumption | ≦0.78 Nm3/kWh (Average at max. load) | ≦0.78 Nm3/kWh (Average at max. load) | ≦0.78 Nm3/kWh (Average at max. load) | ≦0.78 Nm3/kWh (Average at max. load) | ≦0.78 Nm3/kWh (Average at max. load) |
| Start up time | ≦2minute at ambient temperature | ≦2minute at ambient temperature | ≦2minute at ambient temperature | ≦2minute at ambient temperature | ≦2minute at ambient temperature |
| Efficiency of system | ≧42% at peak power | ≧42% at peak power | ≧42% at peak power | ≧42% at peak power | ≧42% at peak power |
| Temperature De-rating | 1.25% per °C over 40°C | 1.25% per °C over 40°C | 1.25% per °C over 40°C | 1.25% per °C over 40°C | 1.25% per °C over 40°C |
| Altitude De-rating | 3.5% per 500m over 1000m | 3.5% per 500m over 1000m | 3.5% per 500m over 1000m | 3.5% per 500m over 1000m | 3.5% per 500m over 1000m |
| Max. noise | Normal operation: <70 dBa at 1="1">70> | Normal operation: <70 dBa at 1="1">70> | Normal operation: <70 dBa at 1="1">70> | Normal operation: <70 dBa at 1="1">70> | Normal operation: <70 dBa at 1="1">70> |
| Storage Temperature | ﹣20⁰ to + 50⁰C Standard | ﹣20⁰ to + 50⁰C Standard | ﹣20⁰ to + 50⁰C Standard | ﹣20⁰ to + 50⁰C Standard | ﹣20⁰ to + 50⁰C Standard |
* additional heating needed when temperature less than 0⁰C, during operation