Need help?

5kW Fuel Cell Stack T-Series

The T-5000 PEM Fuel Cell (5kW) delivers 5,000W of clean, stable backup energy by combining two modular T-2500 units into one highly integrated system. Designed for off-grid telecommunications infrastructure, defense operations, and remote system installations, the T-5000 provides autonomous, mission-critical power where reliability is non-negotiable.
 
This robust dual-stack system includes two 2500W fuel cell stacks, a built-in DC/DC converter, intelligent controller, hydrogen sensor, pressure regulator, RS232 cable, FC +/- cables, 6mm PTFE tubing, and ferrule connectors. Its modular design offers built-in expandability, and the included software allows for voltage range adjustments and real-time performance monitoring. Add a 48V battery for fully automated, continuous operation—ideal for unattended deployments in remote or secure locations.
 
Why Choose the T-5000 PEM Fuel Cell

5kW of Scalable Backup Power – Built from two T-2500 stacks, ideal for telecom towers, defense systems, and remote off-grid installations
Highly Integrated Design – Dual-stack system with DC/DC converter, controller, sensors, tubing, and full cabling package
Modular and Scaliable – Easily expandable with other T-Series units as project requirements grow
Live System Control & Monitoring – RS232-compatible software allows for real-time diagnostics and voltage adjustment
Autonomous Energy Delivery – Pair with a 48V battery for continuous, hands-free power with no manual oversight
Global Delivery & Support – Backed by Horizon’s international logistics network and technical support experts
T-Series 5000

5000W Air Cooled Fuel Cell Stack 

Additional Information 

This fuel cell system comes with a controller, FC connector, RS232 cable, FC +/- cables, output +/- cables, pressure regulator, 6mm PTFE tube, Ferrule Connectors, and a hydrogen sensor.

Because we are unable to keep this product in stock, please fill out a quote request form here so that we can get into touch with you and help you to place an order for this fuel cell stack.  We can also answer any questions you may have and provide proper delivery expectations.  Please feel free to use the quote request form for this fuel cell stack and provide us with information regarding the intended use of this product.  That way we can work with you on helping you to order any additional components that may be needed.

List of T-5000 components:

2 x 2500W fuel cell stack

2 x 2500W controller

2 x fuel cell connector

2 x RS232 cable

2 x FC +/- cables

2 x Output +/- cables

2 x pressure regulator

4 x 8mm PTFE tube (1m)

40 x ferrule connectors

2 x hydrogen sensor

1 x set of cables connecting the modules

5000W Air Cooled Fuel Cell Stack Quick Product Facts

Pressure

Hydrogen Pressure

Hydrogen must be fed into the fuel cell stack at a pressure of 0.55 to 0.75bar.

Temperature

Ambient Temperature

The fuel cell stack operates best in a temperature ranging from 0 to 40° C.

weight

FC Stack Weight

The stack (including fan and casing) weighs 178lbs / 80.6kg.

efficiency

System Efficiency

At peak power the efficiency of the system is 42%.

1

Hydrogen Purity

A fuel of gaseous hydrogen at a minimum purity level of 99.995% is required.

2

Voltage Output

The voltage can be adjusted to between 43.2 and 57.6 volts direct current.

Packing Information

 

  T-1000 T-2500 T-3000 T-5000 T-10000
Power rating 0 to 1000 W @ 20°C and 101.3 kPa 0 to 2500 W @ 20°C and 101.3 kPa 0 to 3000 W @ 20°C and 101.3 kPa 0 to 5000 W @ 20°C and 101.3 kPa 0 to 5000 W @ 20°C and 101.3 kPa
Current Rating 0 to 19A @54V 0 to 47A @54V 0 to 56A @54V 0 to 47A x 2 @54V 0 to 47A x 4 @54V
Voltage Adjustable 43.2 to 57.6 VDC 43.2 to 57.6 VDC 43.2 to 57.6 VDC 43.2 to 57.6 VDC 43.2 to 57.6 VDC
Voltage Ripple ±1V ±1V ±1V ±1V ±1V
Controller Dimension (WxDxH) 430mm x 550mm x 88mm 430mm x 550mm x 88mm 430mm x 550mm x 150mm (430mm x 550mm x 88mm) x 2 (430mm x 550mm x 88mm) x 4
Stack Dimension (WxDxH) 430mm x 550mm x 88mm 430mm x 550mm x 356mm 430mm x 550mm x 356mm (430mm x 550mm x 356mm) x 2 (430mm x 550mm x 356mm) x 4
Controller Weight 10 kg 13.5 kg 15 kg 13.5 x 2 kg 13.5 x 4 kg
Stack Weight 18 kg 40.3 kg 40.3 kg 40.3 x 2 kg 40.3 x 4 kg
Ambient temeprature * -10⁰C to +45⁰C standard -10⁰C to +45⁰C standard -10⁰C to +45⁰C standard -10⁰C to +45⁰C standard -10⁰C to +45⁰C standard
Recommended cold start temp More than 5⁰C More than 5⁰C More than 5⁰C More than 5⁰C More than 5⁰C
Relative Humidity 0‐95% Non‐Condensing 0‐95% Non‐Condensing 0‐95% Non‐Condensing 0‐95% Non‐Condensing 0‐95% Non‐Condensing
Communications RS232 RS232 RS232 RS232 RS232
Standby Power Consumption Approximately<3% at peak power (DC) Approximately<3% at peak power (DC) Approximately<3% at peak power (DC) Approximately<3% at peak power (DC) Approximately<3% at peak power (DC)
Reactants Hydrogen and Air Hydrogen and Air Hydrogen and Air Hydrogen and Air Hydrogen and Air
Cooling Air (integrated cooling fan) Air (integrated cooling fan) Air (integrated cooling fan) Air (integrated cooling fan) Air (integrated cooling fan)
H2 inlet pressure 0.55-0.75bar 0.55-0.75bar 0.55-0.75bar 0.55-0.75bar 0.55-0.75bar
Hydrogen purity ≧99.95% dry H2 ≧99.95% dry H2 ≧99.95% dry H2 ≧99.95% dry H2 ≧99.95% dry H2
Consumption ≦0.78 Nm3/kWh (Average at max. load) ≦0.78 Nm3/kWh (Average at max. load) ≦0.78 Nm3/kWh (Average at max. load) ≦0.78 Nm3/kWh (Average at max. load) ≦0.78 Nm3/kWh (Average at max. load)
Start up time ≦2minute at ambient temperature ≦2minute at ambient temperature ≦2minute at ambient temperature ≦2minute at ambient temperature ≦2minute at ambient temperature
Efficiency of system ≧42% at peak power ≧42% at peak power ≧42% at peak power ≧42% at peak power ≧42% at peak power
Temperature De-rating 1.25% per °C over 40°C 1.25% per °C over 40°C 1.25% per °C over 40°C 1.25% per °C over 40°C 1.25% per °C over 40°C
Altitude De-rating 3.5% per 500m over 1000m 3.5% per 500m over 1000m 3.5% per 500m over 1000m 3.5% per 500m over 1000m 3.5% per 500m over 1000m
Max. noise Normal operation: <70 dBa at 1="1"> Normal operation: <70 dBa at 1="1"> Normal operation: <70 dBa at 1="1"> Normal operation: <70 dBa at 1="1"> Normal operation: <70 dBa at 1="1">
Storage Temperature ﹣20⁰ to + 50⁰C Standard ﹣20⁰ to + 50⁰C Standard ﹣20⁰ to + 50⁰C Standard ﹣20⁰ to + 50⁰C Standard ﹣20⁰ to + 50⁰C Standard

* additional heating needed when temperature less than 0⁰C, during operation

T series
T series
T series

Downloads

Datasheet

pdf [776.21 kB]

User Manual

pdf [2.03 MB]

Brochure You need to be Logged in to download these files

pdf [1.74 MB]

This product is only on demand. Please contact us.

Request a Quote
Loading ...
<